All Others Stuff
Copyright NoticeSFL Services LLC has prepared this document for use only by their staff, agents, customers and prospective customers. Companies, names and data used as examples in this document are fictitious unless otherwise noted. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of SFL Services LLC, who reserve the right to change specifications and other information contained herein without prior notice. The reader should consult SFL Services LLC to determine whether any such changes have been made.Licensing and WarrantyThe terms and conditions governing the licensing of SFL Services LLC software consist solely of those set forth in the written contracts between SFL Services LLC and its customers. Except as expressly provided for in the warranty provisions of those written contracts, no representation or other affirmation of fact contained in this document, including but not limited to statements regarding capacity, suitability for use or performance of products described herein, shall be deemed to be a warranty by SFL Services LLC for any purpose, or give rise to any liability of SFL Services LLC whatsoever.LiabilityIn no event shall SFL Services LLC be liable for any incidental, indirect, special or consequential damages whatsoever (including but not limited to lost profits) arising out of or related to this document or the information contained in it, even if SFL Services LLC had been advised, knew or should have known of the possibility of such damages, and even if they had acted negligently.
Synology - Bag of Tricks
sudo -i
ip link set eth1 down
My DS118 idles at 24% after disabling all the junk.
//run once as root to disable services *you* don't need
synopkg stop pkgctl-SynoFinder synopkg uninstall SynoFinder synopkg stop pkgctl-ActiveInsight synopkg uninstall ActiveInsight synopkg stop pkgctl-ScsiTarget synopkg uninstall ScsiTarget synopkg stop pkgctl-SecureSignIn synopkg uninstall SecureSignIn synopkg stop pkgctl-Python2 synopkg uninstall Python2
//root task disable thumbnails every boot if you're not indexing
cd /var/packages/FileStation/target/etc/conf/ mv thumbd.conf thumbd.conf.bak
Downgrade Synology DSM 7 (to 6)
I thought I would take the time to share how I downgraded my Synonlogy 1019+ from DSM version 7 to version 6.2.x. The reason for this was that after upgrading, I was no longer able to use Syncthing, and I really needed this working ON the NAS itself. After the upgrade to DSM 7, Plex broke initially as well, but I have a tip at the end of how I fixed this (if you are keeping DSM 7).
BACKUP YOUR CURRENT CONFIGURATION!!!!!!
Get Putty. If you have a Mac, you can use Terminal for the first part, but if you've upgraded to the most recent version of OSX, you won't get Telnet in ZSH. So yeah, just use Putty.
In your Control Panel (on the NAS), enable Telnet and SSH.
Login to your NAS via SSH (using Putty or Terminal), using your admin account and password.
Do the following: sudo vi /etc.defaults/VERSION
[ENTER]
when prompted, enter your password
5.Once in the VI editor, press the "i" (eye) key to be able to insert data. Overwrite all content, and replace it with the following:
majorversion="6" minorversion="2" productversion="6.2.3" buildphase="GM" buildnumber="25426" smallfixnumber="0" builddate="2020/07/01" buildtime="06:24:39"
To save, do the following:
[ESC]
:wq!
[ENTER]
sudo reboot [ENTER] (or reboot from the web interface)
Once the NAS reboots, use the Synology Assistant to find it. Follow the prompts to reinstall DSM.
At the screen that prompts you to choose the version of DSM to install, choose the Manual option, and click the link beside it and download version 6. Download the DSM version you want.
Continue the installation process by browsing to, and selecting the DSM version 6 file you just downloaded. As the process continues, you will be met with an error. At this point STOP, the Telnet port will be opened. Do the following:
10. Using Putty, choose the Telnet option, enter the IP address of your NAS, ensure that port 23 is chosen, and connect.
11. Enter "root" as the user, and the password of "101-0101" (without the quotes).
12. Repeat Step 4, except you should not enter "sudo" since you are already root. Repeat Step 5.
13. It took me quite some time to figure out this one issue. When I would go to save the edited file, I kept getting an error, and it did not make sense. Eventually, I figured it out. Repeat step 6, except don't do the combination write and quit (:wq!) command as before. I had to do a write first, then a quit. As below:
Assuming you entered the information from Step 12...
[ESC]
:q [ENTER][ENTER]
:w [ENTER][ENTER]
14. Go back to your browser, and continue the installation of DSM 6.
Good luck.
Bonus Tip if you keep DSM 7:
I removed the original steps to fix Plex if you KEEP DSM 7. According to the user below, simply follow Plex’s instructions by downloading the latest version of Plex and using that. Thank you. I thought I had to choose repair first, then I “fixed” my issue, but apparently it was not necessary.
VMWare - Delete inaccessible datastore
Rename the store
Use the web client to rename each store and a DEL in front of the name
Access the shell of the appliance server and then the database
VMware vCenter Server 8.0.2.00300
Type: vCenter Server with an embedded Platform Services Controller
Connected to service
* List APIs: "help api list"
* List Plugins: "help pi list"
* Launch BASH: "shell"
Command> shell
Shell access is granted to root
root@vcenter80 [ ~ ]#
shell;/opt/vmware/vpostgres/current/bin/psql -d VCDB -U postgres
View the stores
This will give you the ID that is needed to clean up
SELECT * FROM vpx_entity;
Delete the store
This is the delete for cleaning up the inaccessible datastore
DELETE FROM vpx_ds_assignment WHERE ds_id=1015; DELETE FROM vpx_datastore WHERE id=1015; DELETE FROM vpx_vm_ds_space WHERE ds_id=1015; DELETE from vpx_entity where id=1015;
Change the ID and then run the following
DELETE FROM vpx_ds_assignment WHERE ds_id=5015;DELETE FROM vpx_datastore WHERE id=5015;DELETE FROM vpx_vm_ds_space WHERE ds_id=5015;DELETE from vpx_entity where id=5015;
Restart the services
\q;service-control --stop --all && service-control --start --all
Proper Active Directory Time Sync Methods
Network Time Protocol (NTP) is a long-standing standard for computers to synchronize time between systems. NTP can be used to ensure that all synchronized computer clocks maintain the same time within a very small margin, usually measured in milliseconds. While making sure all your devices report the correct time is convenient in and of itself, ensuring proper time settings is paramount to security in ways you might not expect. Here are a few security-related items that rely on accurate time settings to work correctly:
Certificate verification
Kerberos authentication
Log integrity
One-time password (OTP) two-factor authentication
Generally, the best practice setup involves creating a trusted time source for internal clients to use as a reference to sync against. This internal time source in turn syncs against a trusted external time source. Following the trail of time syncing, we would expect time to sync from the trusted external source to the trusted local source to all other clients as seen in Figure 1. You may consider having the Active Directory domain controller (DCs) sync to an external time source independently rather than use a single trusted internal source, but this would cause additional overhead and problems such as clock drift that you may not realize until it becomes an issue.
Figure 1 – Proper syncing from an external time source to a trusted internal source
Take an example where the external time source is no longer available. Your clocks will slowly begin to drift until they eventually desynchronize, causing issues such as failed Kerberos authentication. The worst-case scenario for a single trusted time source is that the entire environment “fails together” but clients still have accurate time relative to each other, allowing your critical services to keep moving. All internal clocks would have the same time even if synchronization to the external source were to stop working.
Because time services are a necessity for any network, there are many trusted sources that offer public NTP servers for clients and other networks to sync against. While not nearly an exhaustive list, the following table lists a few example sources.
Provider
URL
Google
http://time.google.com
CloudFlare
time.cloudflare.com
Microsoft
time.windows.com
Apple
time.apple.com
NIST
time.nist.gov
NTP Project
pool.ntp.org
Microsoft’s Recommendations
Active Directory (AD) has a built-in NTP server configured on DCs. Modern DCs leverage NTP with backward compatibility support for Simple Network Time Protocol (SNTP) used in some older Windows environments such as Windows 2000. In most situations where Active Directory Domain Services (AD DS) is already installed, a Domain Controller makes a great candidate for internal time servers that can support both NTP and SNTP. There are usually multiple DCs in any given environment, so the role of determining the base time for all other DCs and by extension all other clients is the responsibility of the DC with the Primary Domain Controller Emulator (PDCe) Flexible Single-Master Operation (FSMO) role in the forest root domain. Figure 2 shows an example configuration using DCs as time servers.
Figure 2 – Example time sync configuration for a single AD domain
While the PDC emulator will likely be using the standard NTP protocol to sync from an external source, all other DCs, member servers, and client computers joined to the domain will typically be configured to forego use of the NTP protocol for the Microsoft-specific NT5DS time synchronization method. Typically, any client joined to the domain should be configured to use NT5DS to synchronize time through AD automatically. In most situations, no actual client configuration should be required unless an existing configuration that uses NTP needs to be removed.
Multi-Domain Forest NTP Considerations
Time synchronizations for forests that have multiple domains don’t all sync directly with the parent domain PDCe DCs. In a situation where one or more child domains exist, time synchronization can be determined using the following table.
Domain
Device Type
Syncs Time From
Parent
PDCe DC
External time source
Parent
Non-PDCe DC
Parent domain PDCe DC
Parent
Domain-joined client
Parent domain DC
Child
PDCe DC
Any parent domain DC
Child
DC
Any child domain DC
Child
Domain-joined client
Child domain DC
Note: this table assumes the CrossSiteSync flag is set to the Microsoft default of 2; other configurations are possible and will be elaborated on in a future blog post
Configuring a Robust Internal Time Syncing Infrastructure
While it’s trivial to configure external NTP synchronization from the PDCe, it becomes another item to manage and configure in the event of transferring FSMO roles. A more robust solution that would allow for external NTP configurations to be transferred along with the PDC emulator role would be ideal. To this end, the following configuration items are recommended:
Create a Group Policy Windows Management Instrumentation (WMI) filter to target the PDCe role holder.
Create a Group Policy Object (GPO) to allow the PDCe to sync time from a trusted external source, apply the WMI filter you previously created, and link the GPO to the default Domain Controllers organizational unit (OU).
This means that if the PDCe role is transferred from one Windows server to another, Group Policy will enforce external time syncing on the DC with the newly acquired PDCe role. Once the policy for the PDCe is unlinked due to role change, the old PDCe returns to the normal NT5DS synchronization—allowing it to gather time from the new PDCe rather than the originally configured external time source.
Requirements for Configuration
The DC(s) that may be serving as PDCe are allowed to access the configured external trusted time server using the NTP protocol [UDP Port 123].
The DCs not serving as the PDCe are allowed to access the PDCe using the NT5DS protocol [UDP Port 123].
Clients can reach the DCs serving as NTP servers using both the NTP and NT5DS protocol [UDP Port 123].
PDCe DC Role Filter Configuration
The first required step is to create the WMI filter that will be used to ensure only the PDCe is allowed to sync from an external time source. This can be configured from the Microsoft Management Console (MMC) Active Directory Group Policy Management snap-in, as Figure 3 shows.
Right-click the WMI Filters folder and right-click New
Give the new filter a meaningful name, for example PDCe DC Role Filter
Give the new filter a meaningful description such as “ This filter will search for a computer with the PDCe FSMO Role [DomainRole 5] ”
Create a new query by clicking Add
Leave the Namespace field at the default value of root\CIMv2
Enter the following text for the Query value: Select * from Win32_ComputerSystem where DomainRole = 5
Figure 3 – Example role filter to target only the PDCeNote: this query will specifically look for the DomainRole value of 5 which is only used by the DC with the PDCe FSMO role
PDCe NTP Configuration GPO Creation
The next step is to create a GPO that will configure the PDCe to sync time from an external source. This can be configured from the MMC Active Directory Group Policy Management snap-in.
Right-click the Group Policy Objects folder and click New
Give the new GPO a meaningful name such as Configure PDCe Time Server
Select Configure PDCE Time Server GPO and set the WMI Filtering filter to PDCE DC Role Filter
Edit the Configure PDCE Time Server GPO and navigate to: Computer Configuration > Policies > Administrative Templates > System > Windows Time Service > Time Providers
Edit the Configure Windows NTP Client setting and set the following values:
Status
Enabled
NtpServer
http://us.pool.ntp.org ,0x9 http://1.us.pool.ntp.org ,0x9 2.us.pool.ntp.org ,0x9 http://3.us.pool.ntp.org ,0x9;
Type
NTP
CrossSiteSyncFlags
2
ResolvePeerBackoffMinutes
15
ResolvePeerBackoffMaxTimes
7
SpecialPollInterval
3600
EventLogFlags
3
Note: You may choose different external time servers based on your location and needs; these values are only given as an example but will work.
Edit the Enable Windows NTP Client setting and set the following value:
Status : Enabled
Edit the Enable Windows NTP Server setting and set the following value:
Status : Enabled
Exit the Configure PDCE Time Server Group Policy window
Right-click the Domain Controllers OU and select Link an Existing GPO
Select Configure PDCE Time Server and click OK
Testing NTP Configuration on the PDCe
Log on to the PDCe DC and open an administrative CMD prompt
Perform a Group Policy update by entering the following command: gpupdate /force
Confirm that Group Policy has been updated successfully
Check the NTP client configuration by entering the following command: w32tm /query /status
The output should confirm that the source is one of the external time servers configured in the GPO, as seen in Figure 4.
Figure 4 – The PDCe is correctly syncing from an external source
Testing NTP Configuration on a Non-PDCe DC or Client
Log on to a non-PDCe DC and open an administrative CMD prompt
Perform a Group Policy update by entering the following command: gpupdate /force
Confirm that Group Policy has been updated successfully
Check the NTP client configuration by entering the following command: w32tm /query /status
The output should confirm that the source is the PDCe or DC, as seen in Figure 5.
Figure 5 – The DC is correctly syncing time from the PDCe
Final Considerations
Time synchronization is an important yet sometimes overlooked part of security. Luckily, the tools offered through AD allow for a relatively simple time synchronization configuration that proves to be robust and survivable even through FSMO role changes. It may also be worth investigating other NTP configurations, such as configuring DHCP Option #42 to automatically configure NTP sources on your network for non-domain-joined devices.
from: https://www.ravenswoodtechnology.com/in-sync-proper-active-directory-time-sync-methods/
Synology - Backup from Linux
Introduction
This is to setup a hourly MySQL backups and also a full system backup once a week.
Synology Configuration
NFS Configuration
You will need to go to the Control Panel → File Services under the NFS section and turn it on
Then hit APPY
Then go to Shared Folder to setup the share you would like to use for the backups
Linux Configuration
Now login to the Linux server to setup FSTAB to allow the NFS link to work
Edit the “/etc/fstab“
#Custom
bigberta.onling.com:/volume1/Backups /mnt/backups nfs auto,defaults 0 0
Create the directory for the mount
mkdir -p /mnt/backups
After the mount the new NFS drive
mount -a -v
systemctl daemon-reload
To force kill the new mount
umount -l /mnt/backups
Linux - FTP Using Bash
Example of simple bash script ftp client
This script first defines variables such as hostname of the ftp server, username and password and then it creates an ftp session and uploads the specified file into your selected directory:
#!/bin/bash
ftp_site=127.0.0.1
username=ftpuser
passwd=pass
PS3='Select a destination directory: '
# bash select
select path in "." "/test" "public_html/myblog/" "backup/images/"
do
ftp -n $ftp_site<" to something like this
allow="127\.\d+\.\d+\.\d+|::1|0:0:0:0:0:0:0:1|192.168.253.100|192.168.252.2" />
Configure XWiki
Download the war file
cd /opt/tomcat/webapps
wget -O wiki.war https://nexus.xwiki.org/nexus/content/groups/public/org/xwiki/platform/xwiki-platform-distribution-war/15.10.11/xwiki-platform-distribution-war-15.10.11.war
systemctl restart tomcat
Reverse Proxy
Change for reverse proxy settings
sudo vi /opt/tomcat/webapps/wiki/WEB-INF/xwiki.cfg
Change the following in the file
To point to a specific domain
xwiki.home=http://wiki.sflservicesllc.com
Change to use https
xwiki.url.protocol=https
MySQL Setup
After the Tomcat service is restarted move to the XWiki’s WEB-INF/lib directory and download the MySQL JDBC Driver JAR:
su - tomcat
cd /opt/tomcat/webapps/wiki/WEB-INF/lib/
wget https://repo1.maven.org/maven2/mysql/mysql-connector-java/5.1.49/mysql-connector-java-5.1.49.jar
chown tomcat:tomcat mysql-connector-java-5.1.49.jar
MariaDB Setup
After the Tomcat service is restarted move to the XWiki’s WEB-INF/lib directory and download the MariaDB JDBC Driver JAR:
su - tomcat
cd /opt/tomcat/webapps/wiki/WEB-INF/lib/
wget https://dlm.mariadb.com/3852266/Connectors/java/connector-java-3.4.1/mariadb-java-client-3.4.1.jar
chown tomcat:tomcat mariadb-java-client-3.4.1.jar
Open the WEB-INF/hibernate.cfg.xml file and configure XWiki to use MySQL:
vi /opt/tomcat/webapps/wiki/WEB-INF/hibernate.cfg.xml
Comment out the default hsqldb database section and uncomment and edit the MySQL database section as shown below:
Uncomment wither the MySQL Section or the MariaDB section and change the password
xwiki
xwiki_password
Restart the Tomcat service
sudo systemctl restart tomcat
Accessing Tomcat
Open your web browser and navigate to the following below. You should see the default Tomcat landing page.
http://[your_server_ip]:8080/wiki
https://linuxhostsupport.com/blog/how-to-install-xwiki-on-centos-7/
https://reintech.io/blog/installing-configuring-tomcat-rocky-linux-9
Synology - Moving Packages Between Volumes DSM 7.0
Stop the application(s) via the Synology package center.
Make sure that Telnet/SSH is enabled
Login to Synology using SSH and elevate to root .
Make sure that the volume you are moving the application(s) to have the following folders:
@appstore
@apphome
@appconf
@apptemp
If they do not you will have to create them in super user mode “ sudo -i ” for all of the following commands
sudo -i
cd /volume2
mkdir /volume2/@appstore
mkdir /volume2/@apphome
mkdir /volume2/@appconf
mkdir /volume2/@apptemp
Find the application that you need to move on the correct value
Use “ls” against /VolumeX/@appstore to find your package folder name
cd /volume1/@appstore
ls -lart
drwxr-xr-x 15 AudioStation AudioStation 4096 Oct 6 22:37 AudioStation
drwxr-xr-x 16 MediaServer MediaServer 4096 Oct 6 22:40 MediaServer
drwxr-xr-x 9 iTunesServer iTunesServer 4096 Oct 6 22:41 iTunesServer
drwxr-xr-x 23 SurveillanceStation SurveillanceStation 4096 Jan 24 17:13 SurveillanceStation
Use “mv” to move the data between the old and new volume, you may need to create the @appstore folder first.
mv SurveillanceStation /volume2/@appstore/
Now you will need to adjust Synology and relocate the parameters for the application(s) and where it is now moved to. this is done where the packages configurations live in “ /var/packages ”.
cd /var/packages/SurveillanceStation
ls -lrt
lrwxrwxrwx 1 root root 33 Oct 6 22:33 var -> /volume1/@appdata/UniversalViewer
lrwxrwxrwx 1 root root 33 Oct 6 22:33 tmp -> /volume1/@apptemp/UniversalViewer
lrwxrwxrwx 1 root root 34 Oct 6 22:33 target -> /volume1/@appstore/UniversalViewer
lrwxrwxrwx 1 root root 33 Oct 6 22:33 home -> /volume1/@apphome/UniversalViewer
lrwxrwxrwx 1 root root 33 Oct 6 22:33 etc -> /volume1/@appconf/UniversalViewer
Now we have to remove the symbolic links and recreate them to point to volume2 using the “ rm ” to remove and the “ ln -s ” to recreate them.
rm var tmp target home etc
ln -s /volume2/@appdata/UniversalViewer var
ln -s /volume2/@apptemp/UniversalViewer tmp
ln -s /volume2/@appstore/UniversalViewer target
ln -s /volume2/@apphome/UniversalViewer home
ln -s /volume2/@appconf/UniversalViewer etc
Repair your application(s) package in the Synology Package Centre.
It will automatically re-download and restart
Veeam Upgrade
https://www.reddit.com/r/Veeam/comments/1b84qg4/migrate_11_to_12_on_new_hardware/
Disable all jobs, perform necessary backups and snapshots of existing v11 server
Perform upgrade to v12
Post upgrade, take configuration backup
On new v12 server, perform configuration restore
Enable jobs
Decom old VBR server/DB.
Or you can install the same v11 version on the new server, perform the config backup and restore first, then do an in place upgrade of the new server to v12.
Make sure you upgrade any VeeamONE and Enterprise Manager first.
Licensing, you can use the same license on both servers as long as its part of the migration process...only running the same license on two different VBR server in production at the same time is an issue.
Veeam Duplicate UUID
This is to bypass the UUID check if you have restored an old back to new hardware for example a laptop or physical PC.
REGEDIT
To ‘EnableSystemUuidFailover’ key should be added on each Veeam Agent host with non-unique ID. This is the key enabling Veeam failover logic. Name: EnableSystemUuidFailover Path: HKLM\SOFTWARE\Veeam\ Type: DWORD Value: 1 Then a unique ID should be assigned manually on each Agent station. Another Veeam registry should be added on each host for it: Name: SystemUuid Path: HKLM\SOFTWARE\Veeam\ Type: REG_SZ Value: {a custom UUID}
Custom UUID should correspond with the standard UUID format rules, brackets are required. You can use some online generator for it ( https://www.uuidgenerator.net/ ) or put some your own strings there. Rescan protection group and you are deployed now
Disable "Windows recovery image file not found" warning
You can add AgentsDisableRECollectionWarning key here HKEY_LOCAL_MACHINE\SOFTWARE\Veeam\Veeam Backup and Replication to disable this warning.
Name: AgentsDisableRECollectionWarning
Path: HKLM\SOFTWARE\Veeam\
Type: DWORD Value: 1
WordPress - Setup WordPress
Connecting to Your Server
Using PuTTY
Open PuTTY and enter your domain name in the box named Host name (or IP address) and enter the port number used to connect to SSH under Port , and then click Open . You can even save your site settings by entering a name in the Saved Sessions box and by pressing Save . Next time, you can always load the session by selecting your site and clicking Load .
PuTTY will now ask for your username. Enter your username and press Enter . Now you will be asked for your password. Note here that while you are typing your password, you won't see it being typed on the screen. It's hidden for security reasons. Press Enter after you've typed your password, and you will be logged on.
Using Any Other SSH Client or Mac Terminal
Enter the following command in your Terminal client to connect to your site's command-line over SSH:
ssh username@domain.com -p 22
The -p switch tells it to use port number 22. If your host allows SSH over default port 22, you can omit -p and 22 in the above command; otherwise, substitute 22 for your host's SSH port number. After logging in, you will see something like this:
domain.com@username:-$
That's the shell command prompt where you will be typing all your commands from now on.
2. Downloading WordPress
Now that we have logged in to our SSH server, we need to go to the correct directory where we want to set up our blog. Then we download the files and extract them there. Let's say the directory you want your blog to be installed under is blogdemo residing under the public_html directory. In that case, you will use the following command:
cd public_html/blogdemo/
Now that we have reached the correct directory, we will download WordPress using the wget command.
wget http://wordpress.org/latest.tar.gz
$tar xfz latest.tar.gz
The above command downloads the latest WordPress install from their server and extracts the file from it into the blogdemo directory. x , f , and z are parameters which tell the tar command to extract the contents from the specified file using gzip.
Now, after extraction, you will find a wordpress directory under the blogdemo directory containing your install. So to shift the files back to where they should be, use the following commands:
mv wordpress/* ./
This command moves the contents of the wordpress directory into the current directory. Anytime you want to check what's in the current directory, type ls .
If you want, you can use the following commands to delete both the wordpress directory and the archive file you downloaded:
rmdir ./wordpress/
rm -f latest.tar.gz
File Permissions
Correct file permissions from the root folder
When you setup WP you (the webserver) may need write access to the files. So the access rights may need to be loose.
chown www-data:www-data -R * # Let Apache be owner
find . -type d -exec chmod 755 {} \; # Change directory permissions rwxr-xr-x
find . -type f -exec chmod 644 {} \; # Change file permissions rw-r--r--
After the setup you should tighten the access rights , according to Hardening WordPress all files except for wp-content should be writable by your user account only. wp-content must be writable by www-data too.
chown : -R * # Let your useraccount be owner
chown www-data:www-data wp-content # Let apache be owner of wp-content
Maybe you want to change the contents in wp-content later on. In this case you could
temporarily change to the user to www-data with su ,
give wp-content group write access 775 and join the group www-data or
give your user the access rights to the folder using ACLs .
Whatever you do, make sure the files have rw permissions for www-data .
3. Installing WordPress
In this step, we will create the database and corresponding user and associate them together. Then we will use the famous five-minute install of WordPress to finish it off.
Note: Before moving ahead, you will need to check whether you have got the privileges to create a database or not. An easy way to check is to go to your phpMyAdmin and check whether you can create a database from there or not. If you can't, that means you won't be able to follow this step. You should check with your web host if they allow you to do so or not. Most shared web hosts will let you create a database.
First, you need to log in to the MySQL command-line using the following command:
mysql -u username -p
After entering this, you will be asked for your MySQL password. Type your password and you will be shown a screen like this:
Now that we have logged in to the MySQL Server, we will first create a database and will grant the user access to that database. Use the following commands now:
create database dbname;
grant usage on *.* to username@localhost identified by 'password';
grant all privileges on dbname.* to username@localhost;
Don't forget the semi-colon at the end of each MySQL command. The first command creates the database. The second command allows the user to connect to the database. The final command grants all privileges to the user for that database. You can test whether your database creation was successful by running this command:
use dbname;
It should say "database changed". Now you can exit the MySQL command-line by typing exit .
Now fire up the blog in your browser and run the usual WordPress install, and use the database information we used in the third step to set up your wp-config.php and then set up your blog.
Note: New Database User
In our tutorial, we are using an existing database user to connect to the new database. But if you want a separate user for each database, you need to create a new user to access that database. Here's how you should do it.
Once you are inside the MySQL shell, use the following commands to create a new user and set its password.
create user 'dbusername'@'localhost' identified by 'password';
Now go back to Step 3 and run all other commands with this username.
Editing wp-config.php
In our tutorial, I have told you that after doing everything on the shell, you can directly proceed to the install. But some of you might want to edit wp-config.php to add special settings and code. You can only do that via the shell. While you are in your blog directory at the shell, use the following command to fire up the Vim Editor (a command-line shell file editor)
vi ./wp-config.php
Now you will see something like what's shown below:
Press the i key to enter insert mode, and use the arrow keys to move around the file. Once you have made your edits, press the Esc key to exit insert mode. To exit Vim, type : and then type wq and press Enter . This will save your changes and quit Vim.
Increasing Import File Size
Create a .user.ini in the root folder of the WordPress site
upload_max_filesize = 500M
post_max_size = 500M
memory_limit = 500M
max_execution_time = 600
Or you can change the following in the wp-content/plugins/all-in-one-wp-migration/constants.php
define( 'AI1WM_MAX_FILE_SIZE', 2 << 28 );
To the following
define( 'AI1WM_MAX_FILE_SIZE', 2 << 500 );
All in one Import for restore after the file is on the root/wp-content folder and does not require a paid version.
Original
all-in-one-wp-migration-6.7.zip
Forked direct link
All-In-One-WP-Migration-With-Import-master.zip
Download and Install WordPress With the WP-CLI Tool
In this section, I'll show you an even better way to download and install WordPress: with the WP-CLI tool. First, we have to install the WP-CLI tool on the server.
How to Install the WP-CLI Tool
Run the following commands on your server to download, install, and configure the WP-CLI tool.
curl -O https://raw.githubusercontent.com/wp-cli/builds/gh-pages/phar/wp-cli.phar
chmod +x wp-cli.phar
sudo mv wp-cli.phar /usr/local/bin/wp-cli
Let's check if the WP-CLI tool is installed successfully by using the following command.
wp-cli --info
You should see something like this:
OS: Linux 4.15.0-91-generic #92-Ubuntu SMP Fri Feb 28 11:09:48 UTC 2020 x86_64
Shell: /bin/bash
PHP binary: /usr/bin/php7.2
PHP version: 7.2.24-0ubuntu0.18.04.3
php.ini used: /etc/php/7.2/cli/php.ini
WP-CLI root dir: phar://wp-cli.phar/vendor/wp-cli/wp-cli
WP-CLI vendor dir: phar://wp-cli.phar/vendor
WP_CLI phar path: /etc/init.d
WP-CLI packages dir:
WP-CLI global config:
WP-CLI project config:
WP-CLI version: 2.4.0
Download and Install WordPress
Let's download the latest version of WordPress first.
wp-cli core download
If the download is successful, you'll see something like the following:
Downloading WordPress 5.5.1 (en_US)...
md5 hash verified: 72c6f56b4818ffd0e6e6a4ed8f3e8d4e
Success: WordPress downloaded.
So we've downloaded the WordPress codebase now.
Next, it's time to create the wp-config.php file. We can do it with the help of the following command. Replace the placeholders with the actual values. I assume that you've already created the database which you would like to use with WordPress.
$wp-cli config create --dbname=YOUR_DB_NAME --dbuser=YOUR_DB_USERNAME --dbpass=YOUR_DB_PASSWORD --locale=en_DB
Success: Generated 'wp-config.php' file.
Finally, let's run the following command, which installs WordPress.
$wp-cli core install --url=YOUR_DOMAIN_NAME --title=YOUR_BLOG_TITLE --admin_user=ADMIN_USERNAME --admin_password=ADMIN_PASSWORD --admin_email=ADMIN_EMAIL
Success: WordPress installed successfully.
And with that, WordPress is installed successfully on your server!
In fact, the WP-CLI tool is capable of doing a lot more than just installation. It allows you to manage plugins and themes and do any necessary version updates as well.
VMWare - Install Windows 11 on vCenter 8 without TMP 2.0
Create a VMWare to host Windows 11 without having a virtual TMP or device installed.
Once you are at this step you have to hit " Shift-F10 " to open up the command prompt
Once the command prompt window is opened type " regedit "
Once opened then navigate to " HKEY_LOCAL_MACHINE, SYSTEM, Setup " and then right-click and add a " New, Key "
Add the key called " LabConfig " then right-click on the " LabConfig " and add a new " DWORD Value "
Add the new value called " ByPassTPMCheck " with a hexdecimal of " 1 "
Close every window then click on " Install Now " but do not reboot or the new added key will be lost.
File Transfer - Using FTP LFTP commands
FTP
Commands
to resume a single file upload using the built-in ftp command you will need to know how many bytes of the file you have already sent. This should be accessible by using ls . Then you use the following sequence to restart your upload replacing <#> with the number of bytes already sent and with the filename you are uploading.
restart <#>
put
If the server allows it you should receive a message such as the following...
350 Restart position accepted (<#>).
150 Ok to send data.
This will resume your upload.
LFTP
Using the LFTP command this allows you to restart a died ftp session
Commands
The following command is the login to the server and go to the folder you are placing the file in
lftp user:pass@host/path/to/folder
lftp user:pass@host/path/to/folder cd ok, cwd=/path/to/folder lftp user@host:/path/to/folder> reput file.ext ---> TYPE I <--- 200 Type set to I ---> SIZE file.ext <--- 213 11842837120 ---> PASV <--- 227 Entering Passive Mode (10,211,14,15,220,70). ---- Connecting data socket to (10.211.14.15) port 56390 ---- Data connection established ---> ALLO 20769244058 <--- 202 No storage allocation necessary ---> REST 11842837120 <--- 350 Restarting at 11842837120. Send STORE or RETRIEVE to initiate transfer ---> STOR file.ext <--- 150 Opening BINARY mode data connection for file.ext `file.ext' at 6756302848 (32%) 31.50M/s eta:7m [Sending data]
This command is to restart the failed FTP replace the "file.txt" with your file
reput file.txt
After a quick search, there's a command line program called lfvi sftp that provides ftp mirroring functionality.
Adapted from a guide here , something like this should do the trick:
#!/bin/bash
HOST='address.co.uk'
USER='myuser'
PASS='mypass'
TARGETFOLDER='/public_html/java/desktop/'
SOURCEFOLDER='deploy/'
lftp -f "
open $HOST
user $USER $PASS
lcd $SOURCEFOLDER
mirror --reverse --delete --verbose $SOURCEFOLDER $TARGETFOLDER
bye
"
I'd suggest you'd do it without the --delete until you're sure you've got the arguments right!
File Transfer - WPUT
WPUT
This is to resume a files transfer using wput instead ftp or lftp commands and can be used in Windows or Linux
WPUT Commands
Here is an example how wput continues upload after connection problems:
wput -v -u -B upload.zip ftp://login:pass@server.com/dir/upload.zip
--20:14:23-- `upload.zip'
=> ftp://login:xxxxx@111.111.111.111:21/dir/upload.zip
Connecting to 111.111.111.111:21... connected!
Logging in as login ... Logged in!
==> CWD dir
==> TYPE I ... done.
==> SIZE upload.zip ... done (4313 bytes)
==> PASV ... done.
==> REST 3584 ... done.
==> STOR upload.zip ... done.
Length: 902,153,406 [902,149,822 to go]
7% [======> ] 65,658,368 194.0K/s ETA 1:10hError: Error encountered during uploading data (Operation now in progress)
==> ABOR ... Error: recv() timed out. No data received
Receive-Warning: read() timed out. Read '' so far.
failed.
Waiting 10 seconds... Error: recv() timed out. No data received
Receive-Warning: read() timed out. Read '' so far.
Connecting to 111.111.111.111:21... connected!
Logging in as login ... Logged in!
==> CWD dir
==> TYPE I ... done.
==> SIZE upload.zip ... done (65247144 bytes)
==> PASV ... done.
==> REST 65246208 ... done.
==> STOR upload.zip ... done.
Length: 902,153,406 [836,907,198 to go]
9% [++++++==>
File Transfer - CURL
CURL
This is the resume a file transfer using curl instead ftp or lftp commands and can be used in Windows or Linux
CURL Commands
curl -C - --upload-file source_file ftp://destination.server.com/
Asus - OpenVPN Site to Site or Point to Point
ASUS Asuswrt Merlin
Most of the documents online are missing steps or the folks writing the document are assuming that the folks setting this up are network traffic wizards.
GOAL:
With one of the Asus routers being the server and the other being a client, we want to be able from either side hit IPs or hostnames of any of any device.
Both Routers:
VPN Type: TUN as TAP maybe overkill for this case
Protocol: UDP
Static Routes: Both servers
When you export the OpenVPN certificates from the router (as opposed to supplying your own), they have the CN set as ‘ client ’. This is relevant/confusing for the server config, as our other router is a client named client.
Server:
ASUS RT-AC5300 with 192.168.53.1/24
Interface Type
TUN TAP
Protocol
TCP UDP
Server Port
(Default : 1194)
Authentication Mode
TLS Static Key
Keys and Certificates
Username/Password Authentication
Yes No
TLS control channel security (tls-auth / tls-crypt)
Disable
Bi-directional Auth
Incoming Auth (0)
Outgoing Auth (1)
Encrypt channel
HMAC Authentication
Default
None
MD 5
SHA 1
SHA 224
SHA 256
SHA 384
SHA 512
RIPEMD 160
RSA MD4
VPN Subnet / Netmask
Advertise DNS to clients
Yes No
Data ciphers
Compression
Disable
None
LZO
LZO Adaptive
LZ4
LZ4-V2
Log verbosity
(Between 0 and 6. Default: 3)
Manage Client-Specific Options
Yes No
Allow Client <-> Client
Yes No
Allow only specified clients
Yes No
Allowed Clients
Common Name(CN)
Subnet
Mask
Push
Add / Delete
No
Yes
client
192.168.51.0
255.255.255.0
Yes
Custom Configuration
reneg-sec 432000 push "route 192.168.53.0 255.255.255.0" route 192.168.51.0 255.255.255.0
Custom Explained:
reneg-sec 432000 #optional
push "route 192.168.53.0 255.255.255.0" #server LAN IP
route 192.168.51.0 255.255.255.0 #client LAN IP
Export the .ovpn files from the new server config
Client:
ASUS RT-AC5300 with 192.168.51.1/24
Import .ovpn config file exported from server, to set the certificates and some of the basic settings.
Select client instance
1: Site-to-Site HOUSE
2: Client 2
3: Client 3
4: Client 4
5: Client 5
Service state
Automatic start at boot time
Yes No
Description
Import .ovpn file
Network Settings
Interface Type
TUN TAP
Protocol
TCP UDP
Server Address and Port
Address: XXXXXXX.asuscomm.com Port:
Create NAT on tunnel
Yes No Routes must be configured manually.
Inbound Firewall
Block Allow
Accept DNS Configuration
Disabled
Relaxed
Strict
Exclusive
Redirect Internet traffic through tunnel
No
Yes (all)
VPN Director (policy rules)
Authentication Settings
Authentication Mode
TLS Static Key
Username/Password Authentication
Yes No
Crypto Settings
Keys and Certificates
Data ciphers
TLS control channel security (tls-auth / tls-crypt)
Disabled
Bi-directional Auth
Incoming Auth (0)
Outgoing Auth (1)
Encrypt Channel
Encrypt Channel V2
Auth digest
Default
None
DSA
DSA-SHA
DSA-SHA1
DSA-SHA1-old
ecdsa-with-SHA1
MD4
MD5
MDC2
RIPEMD160
RSA-MD4
RSA-MD5
RSA-MDC2
RSA-RIPEMD160
RSA-SHA
RSA-SHA1
RSA-SHA1-2
RSA-SHA224
RSA-SHA256
RSA-SHA384
RSA-SHA512
SHA
SHA1
SHA224
SHA256
SHA384
SHA512
whirlpool
Advanced Settings
Log verbosity
(Between 0 and 6. Default: 3)
Compression
Disabled
None
LZO
LZO Adaptive
LZ4
LZ4-V2
Stub
Stub-V2
TLS Renegotiation Time
(in seconds, -1 for default)
Connection Retry attempts
(0 for infinite)
Verify Server Certificate Name
No
Common Name
Common Name Prefix
Subject
Custom Configuration
resolv-retry infinite float keepalive 15 60 remote-cert-tls server
Applied the "automatic start at boot time"
Turn on the client VPN
Server Connection:
OpenVPN Server 2 - Running
Clients
Common Name Username
Real Address Virtual Address
MBytes Received
MBytes Sent
Connected Since
client
XXX.XXX.XXX.XXX:47361 10.100.100.2
7305.28
2561.14
2024-12-22 09:49:57
Routes
Virtual Address
Common Name
Real Address
Last Ref
192.168.51.217C
client
XXX.XXX.XXX.XXX:47361
2024-12-22 11:03:29
192.168.51.1C
client
XXX.XXX.XXX.XXX:47361
2024-12-22 11:03:31
192.168.51.15C
client
XXX.XXX.XXX.XXX:47361
2024-12-22 11:03:36
10.100.100.2
client
XXX.XXX.XXX.XXX:47361
2024-12-22 11:03:50
192.168.51.109C
client
XXX.XXX.XXX.XXX:47361
2024-12-22 11:03:28
192.168.51.145C
client
XXX.XXX.XXX.XXX:47361
2024-12-22 11:03:50
192.168.51.10C
client
XXX.XXX.XXX.XXX:47361
2024-12-22 11:03:31
192.168.51.101C
client
XXX.XXX.XXX.XXX:47361
2024-12-22 11:03:25
192.168.51.140C
client
XXX.XXX.XXX.XXX:47361
2024-12-22 11:03:40
192.168.51.9C
client
XXX.XXX.XXX.XXX:47361
2024-12-22 11:03:50
192.168.51.23C
client
XXX.XXX.XXX.XXX:47361
2024-12-22 11:03:44
Confusion:
The problem is that from the server I cannot access the the LAN on the client side without adding a route vis the JFFS scripts folder using the "nat-start" script.
#!/bin/sh
#https://github.com/RMerl/asuswrt-merlin.ng/wiki/User-scripts
#
DATE=$(date +"%Y-%m-%d-%H%M%S")
echo "deleting the route to router if it exists" $DATE >> /tmp/nat-start.log
route delete -net 192.168.51.0 netmask 255.255.255.0 gw 10.100.100.2
echo "done deleting the route" $DATE >> /tmp/nat-start.log
echo "adding route to router" $DATE >> /tmp/nat-start.log
route add -net 192.168.51.0 netmask 255.255.255.0 gw 10.100.100.2
echo "done adding route to router" $DATE >> /tmp/nat-start.log
References:
https://medium.com/@kylemattimore/asuswrt-merlin-openvpn-tunnel-site-to-site-69b9011b079a
https://www.senia.org/2018/03/12/router-to-router-vpn-tunnel-using-asus-routers/
https://www.asus.com/us/support/faq/1011706/
MarkDown - Guide .md
# Markdown Cheat Sheet
Thanks for visiting [SFL Services LLC](https://www.sflservicesllc.com)!
This Markdown cheat sheet provides a quick overview of all the Markdown syntax elements. It can’t cover every edge case, so if you need more information about any of these elements, refer to the reference guides for [basic syntax](https://www.markdownguide.org/basic-syntax/) and [extended syntax](https://www.markdownguide.org/extended-syntax/).
## Basic Syntax
These are the elements outlined in John Gruber’s original design document. All Markdown applications support these elements.
### Heading
# H1
## H2
### H3
### Bold
**bold text**
### Italic
*italicized text*
### Blockquote
> blockquote
### Ordered List
1. First item
2. Second item
3. Third item
### Unordered List
- First item
- Second item
- Third item
### Code
`code`
### Horizontal Rule
---
### Link
[Markdown Guide](https://www.markdownguide.org)
### Image

## Extended Syntax
These elements extend the basic syntax by adding additional features. Not all Markdown applications support these elements.
### Table
| Syntax | Description |
| ----------- | ----------- |
| Header | Title |
| Paragraph | Text |
### Fenced Code Block
```
{
"firstName": "John",
"lastName": "Smith",
"age": 25
}
```
### Footnote
Here's a sentence with a footnote. [^1]
[^1]: This is the footnote.
### Heading ID
### My Great Heading {#custom-id}
### Definition List
term
: definition
### Strikethrough
~~The world is flat.~~
### Task List
- [x] Write the press release
- [ ] Update the website
- [ ] Contact the media
### Emoji
That is so funny! :joy:
(See also [Copying and Pasting Emoji](https://www.markdownguide.org/extended-syntax/#copying-and-pasting-emoji))
### Highlight
I need to highlight these ==very important words==.
### Subscript
H~2~O
### Superscript
X^2^
Certificate - PKCS12
https://stackoverflow.com/questions/68832952/need-a-little-help-to-generate-p12-cert
https://stackoverflow.com/questions/10175812/how-to-generate-a-self-signed-ssl-certificate-using-openssl?rq=1
DELL - XPS Killer Wifi
I was only getting 1.5mb transfer and 60mb web download
WARNING -- Changing the registry can break your machine if done wrong!!! Do so at your own risk!
I had (sounds like) the same WiFi issues you are having. I was able to "fix" it with a registry hack. Go to this key Computer\HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Power\PowerSettings\ 19cbb8fa-5279-450e-9fac-8a3d5fedd0c1 and create a value (if not there) Attributes with a DWORD value of 2.
Go a little further down, under the above key to Computer\HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Power\PowerSettings\19cbb8fa-5279-450e-9fac-8a3d5fedd0c1\12bbebe6-58d6-4636-95bb-3217ef867c1a\ DefaultPowerSchemeValues\381b4222-f694-41f0-9685-ff5bb260df2e and add the same Attributes value here or set it to 2 if it's already there. Under this key, change the DCSettingIndex to 0 (zero) to match the ACSettingIndex.
This makes the WiFi card use full power on battery under the Balanced Power Plan which is the default plan.
Also mentioned in my previous posts was to remove all the Killer software and use the Intel drivers instead. The current version works fine. Of course download the Intel drivers before removing the Killer stuff.
This did not fix the issue by itself but trust the Intel drivers more.
Caffeine Hack - Got caught with Caffeine installed
Hack
Click Start, then type Powershell and it should show up.
Type notepad $profile to open your default profile.
This will likely be blank if this is the first time doing this.
Paste the following code:
function idle {
$wshell = New-Object -ComObject wscript.shell;
"Press CTRL+C to cancel."
while ($true) {
$wshell.SendKeys('+')
Sleep 60
}
}
Close PowerShell, then re-open it (see step one).
Type idle and hit enter.
Optional: autorun you can add idle to line 9, and when opening PowerShell it will auto run
This function just presses the shift key every minute. It's less intrusive than mouse wigglers..
Updated Version
Save this to your profile, and then you can run it indefinitely using idle or set a duration in minutes by adding it at the end idle 28800 .
You can even have it do the math for you. So 60 mins * 8 hours would be idle (60*8) .
You can get even fancier if you know what time you need to clock out.
# If you stop working at 5pm (17:00) then you could use this:
$peaceout = (get-date 17:00)
idle ($peaceout - (get-date)).TotalMinutes
This part goes in your profile. Remember, if you make changes to your profile you will need to close and reopen any PowerShell terminals for them to pick up the changes.
function idle {
param(
[int]$Duration = -1 # Duration in Minutes
)
$wshell = New-Object -ComObject wscript.shell;
'Press CTRL+C to cancel.'
$idle = $true
while ($idle) {
$wshell.SendKeys('+')
if ($Duration -eq 0) {
$idle = $false
'Time Expired.'
break
}
elseif ($Duration -gt 0) {
write-host -NoNewline "`r$Duration min(s) remaining."
$Duration--
}
Start-Sleep 60
}
}
For both you have to save the file under my documents in the following folder and name the file the following:
\Documents\WindowsPowerShell\Microsoft.PowerShell_profile.ps1
Script Hack
param(
[switch]$Indefinite,
[int]$Minutes = 0
)
if ($Indefinite) {
Write-Host "Keeping system awake indefinitely. Press Ctrl+C to stop."
while ($true) {
[System.Windows.Forms.Cursor]::Position
Start-Sleep -Seconds 60
}
} elseif ($Minutes -gt 0) {
Write-Host "Keeping system awake for $Minutes minutes. This window will close automatically when done."
$endTime = (Get-Date).AddMinutes($Minutes)
while ((Get-Date) -lt $endTime) {
[System.Windows.Forms.Cursor]::Position
Start-Sleep -Seconds 60
}
Write-Host "Time's up!"
} else {
Write-Host "Please specify either -Indefinite or -Minutes ."
}
To Use the Script:
To keep the system awake indefinitely, run:
.\keep-awake.ps1 -Indefinite
To keep the system awake for a specific number of minutes (e.g., 30 minutes), run:
.\keep-awake.ps1 -Minutes 30
Synology - Host Unifi for FREE on Synology NAS
All you have to do is ass a scheduled task scripts under tasks and run the following
docker run -d --name=Unifi-Controller \
-p 3478:3478/udp \
-p 10001:10001/udp \
-p 5514:5514/udp \
-p 8080:8080 \
-p 8443:8443 \
-p 8880:8880 \
-p 8843:8843 \
-e PUID=1026 \
-e PGID=100 \
-e TZ=Europe/London \
-v /volume1/docker/unifi:/config \
--restart always \
ghcr.io/linuxserver/unifi-controller
Concrete - Dry Pour Schedule
Synology - Upgrade 1515+ to 1517+
Worked like a charm
https://github.com/prt1999/Synology_model_upgrade
Ran the above process
Forum Discussions
https://xpenology.com/forum/topic/69328-converting-ds1515-into-ds1517-dsm-72/page/3/
https://xpenology.com/forum/topic/69328-converting-ds1515-into-ds1517-dsm-72/
Revert Back to 1515+
Synology DOM module pinout
Plug into the 2nd row, i.e. straight pins, with normal USB assignment. 2 red 4 white 6 green 8 black
PiHole - Configuration
This is a great link for pi-installation
https://www.crosstalksolutions.com/the-worlds-greatest-pi-hole-and-unbound-tutorial-2023/
ESXi - UPS Nut Installation
Vmware ESXi NUT Client Installation and Configuration
Requirements
You must have a NUT server connected to a UPS and configured in your environment.
SSH must be enabled on your ESXi installation
Community acceptance level must be enabled on your ESXi installation in order to install the client
Download
Download the latest NutClient-ESXi-x.x.x-x.x.x-offline_bundle.zip package from: https://github.com/rgc2000/NutClient-ESXi/releases .
Install
Secure copy the NutClient-ESXi-x.x.x-x.x.x-offline_bundle.zip to your ESXi server’s /tmp directory by either using WinSCP/pscp in Windows or scp in Linux.
Set ESXi Community Acceptance level:
esxcli software acceptance set --level=CommunitySupported
If you get the following error:
[AcceptanceConfigError] Secure Boot enabled: Cannot change acceptance level to community. Please refer to the log file for more details.
You must disable Secure Boot in your computer BIOS and re-try the installation again.
Install bundle:
esxcli software vib install -d /tmp/NutClient-ESXi-x.x.x-x.x.x-offline_bundle.zip
If installation was successful you should see the following output:
Installation Result
Message: Operation finished successfully.
Reboot Required: false
VIBs Installed: Margar_bootbank_upsmon_x.x.x-x.x.x
VIBs Removed:
VIBs Skipped:
You can now delete the files in the /tmp directory and disable the SSH service if desired.
ESXi Configuration
In the ESXi Web client, navigate to Host —> Manage —> System —> Advanced Settings . In the Search box enter UserVars . Nut (Figure 1).
Figure 1
Configure the following variables:
NutUpsName: Name of the UPS on the NUT server (in the form of inverter_name@server_name or server_ip). Several inverters can be entered separated by a space. There will be no system shutdown until the last UPS still standing has given the shutdown command.
NutUser: Name of the NUT server login account
NutPassword: NUT Server Connection Account Password
NutFinalDelay: Seconds to wait after receiving the low battery event to shut down the system
NutSendMail: Set to 1 for the NUT client to send an e-mail to each important event of the UPS
NutMailTo: E-mail address to send UPS events to
In the ESXi Web client, navigate to Host —> Manage —> Services —> NutClient —> Actions —> Policy —> Start and Stop with Host (Figure 2).
Figure 2
In the ESXi Web client, navigate to Host —> Manage —> Services —> NutClient —> Actions —> Start (Figure 3).
Figure 3
Tips
Use the ESXi host configuration tab in the vSphere Client to decide how to start and stop (or suspend) virtual machines. This order will be respected by the UPS shutdown procedure.
The clean shutdown of the OS in the virtual machines is only possible if the vmware tools are installed.
To uninstall the NUT client, use the following command:
esxcli software vib remove -n upsmon
To update the NUT client, use the following command:
esxcli software vib update -d /tmp/NutClient-ESXi-x.x.x-x.x.x-offline_bundle.zip
To estimate the time needed for the server to shut down on UPS alert, type the command below on the host ESXi (by ssh or on the console). The shutdown procedure is immediately started:
/opt/nut/sbin/upsmon -c fsd
If the NUT Client is configured correctly, the ESXi /var/log/syslog.log should have a message similar to below where ups@UPSHOST is the ups name and the UPS host you setup earlier :
2019-09-22T13:28:07Z upsmon[2111424]: Communications with UPS ups@UPSHOST established
Synology - Flash uboot ROM
This guide describes a method how to restore u-boot if the flash has been completely erased. This situation can arise if there was a power loss during u-boot upgrade or you accidentally deleted the boatloader while playing with the u-boot commands like I did. There are many reasons why the DiskStation fails to boot, but as long as the u-boot bootloader partition is not destroyed, you can repair the flash image using the u-boot serial flash subsystem. This guide is for all who are sure that u-boot has been corrupted and that there is no other way to recover. The solution is to physically replace the corrupted flash chip and restore its original content. I will be using a Dangerous Prototypes Buspirate for serial console access and to flash the firmware externally onto a brand new flash IC. This of course will void your warranty as you have to replace the old chip with the new one. In case you are not experienced with soldering you will risk destroying the mainboard, but in my opinion this is still better than throwing the bricked unit away. The following steps involve the preparation of the flash.rom image, programming and replacing the old chip. The new installation will be verified with the serial console. 1. Download and extract firmware image This guide is for a DS213j, but should work equally on other NAS. https://global.download.synology.com/download/DSM/release/6.2/23739/DSM_DS213j_23739.pat The pat file is an uncompressed tar archive: $ tar -xvf DSM_DS213j_4458.pat The files we need are: - uboot_DS213jv10.bin: u-boot - zImage: kernel - rd.bin: initrd 2. Prepare the flash.rom image The size of the flash chip on the DS213j is 64Mbit, so we need an 8MB large image. We first recall the flash layout to get the right offsets: 00000000:000bffff RedBoot (uboot) 000c0000:0038ffff zImage 00390000:007cffff rd.gz 007d0000:007dffff vender 007e0000:007effff RedBoot_Config 007f0000:007fffff FIS_directory Create an empty flash image of 8 MB size filled with zeros: $ dd if=/dev/zero of=flash.rom bs=1024 count=8192 Copy the uboot image to the beginning of the file not truncating the rest: $ dd if=uboot_DS213jv10.bin of=flash.rom conv=notrunc Now copy the kernel image at the right offset. dd cannot directly use hexadecimal values. These have to be converted by the shell: $ dd if=zImage of=flash.rom bs=1 seek=$((0xc0000)) conv=notrunc Next is the initrd image: $ dd if=rd.bin of=flash.rom bs=1 seek=$((0x390000)) conv=notrunc Then comes the vender partition. This is not provided in the download of the firmaware as this is unique to your DiskStation and written only once in the factory. It contains the serial number and the MAC address, which can be found on the sticker at the back of the case. The DiskStation will boot without the vender information, but without the MAC address it will assign a random MAC at each boot. This will annoy DHCP servers as they serve a new IP on every reboot. Automatic firmware updates and the DS Assistant rely on the MAC address as well. For the next step you will need the serial number and original MAC from the sticker and a hex editor (I use hexeditor). First we create an empty 64 kB vender partition: $ dd if=/dev/zero of=vender.img bs=1024 count=64 The MAC address is stored in the first 6 bytes and the 7th byte contains a checksum. The checksum is calculated by taking the sum of the bytes in the MAC address. The following C program can be used to calculate the checksum. The checksum is stored in an unsigned char, which is not large enough to store the total. It will flow over give the rest, which is larger than multiples of 256 bytes: #include int main() { unsigned char chksum = 0; int i = 0; unsigned char rgAddr[6] = {0x00, 0x11, 0x32, 0xFF, 0xFF, 0xFF}; for (i = 0; i < 6; i++) { chksum += rgAddr[i]; } printf("Checksum: 0x%X\n", chksum); return 0; } The first three bytes are the Synology part, the last three bytes needs to be changed to your MAC address. Compile with $ gcc -o checksum mac_checksum.c This MAC example 00:11:32:FF:FF:FF will give a checksum of 0x40. Insert these bytes into the image: $ hexeditor -b vender.img 00000000 00 11 32 FF FF FF 40 The serial number is written like this. For example: SN=1350LAN009999,CHK=999 00000020 53 4e 3d 31 33 35 30 4c 41 4e 30 30 31 39 39 39 00000030 2c 43 48 4b 3d 39 39 39 Use an ascii to hex converter to generate the hex values. The checksum is calculated on next reboot automatically and can be inserted later. We use a dummy of 999 for now. Once u-boot is working again, you can flash the updated vender image from u-boot (see below how to do this). Now insert the vender data into the flash image: $ dd if=vender.img of=flash.rom bs=1 seek=$((0x7d0000)) The flash.rom image is now ready to be flashed onto the chip. The RedBoot_Config and FIS_directory partitions are not needed. 3. Flash the rom image to the new chip The flash chip on the DS213j is a Micron 25Q064A 13E40 64Mbit serial flash. I bought mine here https://hbe-shop.de/Art-2253680-MICRON-N25Q064A13ESE40E-FLASH-SERIELL-64MB-3V-8WSOIC What you also need is a SOIC/DIL 8POL adapter PCB to connect the IC to a breadboard: https://hbe-shop.de/Art-1136592-ARIES-08-350000-11-RC-ADAPTER-SOIC-DIL-8POL For the SPI programmer and 3.3V TTL-USB Level shifter I use a Dangerous Prototypes Buspirate: http://dangerousprototypes.com/docs/Bus_Pirate The Buspirate is a multi purpose debugging and prototyping device that has SPI, JTAG, UART and I2C modes. Solder the IC onto the SOIC adapter and then you can use breadboard to connect the Buspirate with the following circuit ( http://flashrom.org/Bus_Pirate ): For the actual programming of the flash.rom image I used flashrom ( http://flashrom.org/Flashrom ), which supports the Buspirate programmer directly: $ sudo flashrom -c "N25Q064..3E" -V -p buspirate_spi:dev=/dev/ttyUSB0,pullups=on -w flash.rom Now we are set to replace the flash chip on the main board. 4. Replace the flash chip on main board This is the most difficult part and if you are inexperienced with a soldering iron you should get some practise by de-soldering IC's from old motherboards or scrap electronics. Did I mention that touching the DiskStation PCB with a soldering iron will void your warranty? To de-solder the flash chip the trick is to apply plenty of solder over all pins. The pins will be connected through a thick layer of solder and this will distribute the heat over the pins and keep the solder liquid long enough. This looks messy at first, but it is then possible to apply heat to both sides of the chip simultaneously and lift the IC from the PCB without damaging the pins. If you were successful in de-soldering the flash, you could even spare yourself the hassle of buying a new chip and flashing the old one. I use de-soldering wick to clean the pins of the IC and the pads on the PCB. Then I remove residue flux from the PCB with residue cleaner or isopropanol using an old toothbrush. With the same technique you have to de-solder the IC from the SOIC adapter. Before soldering the reprogrammed chip back in, make sure the pads are free from old solder and shiny clean. Then fix the chip on the board with tape and apply very little solder to two opposite pins first, and afterwards apply solder to the remaining pins. 5. Connecting a serial console Information on how to connect to the serial console can be found here: http://www.fr.netbsd.org/ports/sandpoint/instSynology.html The serial console of the DS213j is available at the 6 pin jumper next to the 3 pin fan connector. Connect the BusPirate pins GND, MISO and MOSI to the jumper pins 2, 4 and 6. Pin Function BusPirate 1 3.3 V 2 GND GND 4 TX MISO (RX) 6 RX MOSI (TX) Start your favourite terminal program and put the BusPirate into UART transparent bridge mode. $ script -f -c "picocom -b 115200 /dev/ttyUSB0" session.log Now it is time to power on the DiskStation and watch the output on the console. If the re-flashing was successful, you should see u-boot loading kernel and initrd images. If you still have DSM installed on the hard drives, the DiskStation should boot normally now, otherwise it will stop at the initrd prompt. You could use the DS Assistant to do a fresh DSM install. Congratulations, you are almost there! 6. Flashing the vendor image using u-boot The DiskStation will complain that the serial number checksum does not match the one provided (999) and prints the correct checksum on the console. Write it down and update the vender.img with the correct serial number using hexeditor. EDIT: The checksum of the 13 digit serial number equals to the sum of the individual character bytes, for example SN=1350LAN009999,CHK=744 Now reboot and interrupt the boot process with CTRL-C to get to the u-boot prompt. Copy the vender.img to a TFTP server and set the Diskstation IP with ipaddr and the TFTP server address with serverip. Then transfer the image to memory address 0x2000000: Marvell>> setenv ipaddr 192.168.1.50 Marvell>> setenv serverip 192.168.1.10 Marvell>> tftpboot 0x2000000 vender.img Now initialise the flash subsystem, erase mtd3 partition and write the 64 kB vender.img to the correct address 0x7d0000: Marvell>> sf probe 0 Marvell>> sf erase 0x7d0000 10000 Marvell>> sf write 0x2000000 0x7d0000 0x10000 Marvell>> reset The DiskStation is now restored to a fully working condition. If further problems arise, it is always a good idea to connect the serial console first to see if u-boot is still working. From here you can manually flash new kernel and initrd images or fix problems with the network. Have a good day! Alexander
https://community.synology.com/enu/forum/17/post/69287
HPE - iLO4 Reflash after Not Responsive 380p Gen8
iLO 4 firmware in Direct Mode
Download Online ROM Flash Component for Linux - HPE Integrated Lights-Out 4 (CP######.scexe)
https://support.hpe.com/connect/s/product?language=en_US&ismnp=0&l5oid=5219994&cep=on&kmpmoid=5219994&tab=driversAndSoftware&driversAndSoftwareFilter=8000029
Attached is 2.82 version of iLO4 CP053894.scexe
Download Service Pack for ProLiant 2016+ (search on torrents) version 8.1 or use this ISO
Using HP USB Key Utility for Windows, we create a bootable flash drive from the SPP image.
For Windows use RUFUS https://rufus.ie/en/ to create a usb boot from the SPP .iso file
For Linux installation use https://unetbootin.github.io/ to create a usb boot
Copy CP053894.scexe to the finished flash drive in /hp/swpackages
Turn off the power, remove the case. On the system board, find the main dip switch (System maintenance switch) and turn the first (S1) switch to the ON position
Load the server from the SPP flash drive
Once on the image screen you need to select Interactive mode and when the main menu loads very slowly
press ctrl + alt + d + b + x to launch the console
Run:
You need to enter a simple magic command:
rmmod hpilo
then Run:
sh /mnt/bootdevice/hp/swpackages/CP027578.scexe --direct
After successful iLO flashing, turn off the power and return the first (S1) switch back (OFF).
VMWare - Copy and Paste from Console to VM
On any Powered Off VM, click the " Advanced Parameters " tab.
Click filter icon of Attribute column. Search for 3 items' names, check if they already exist. If yes, edit their corresponding values. If not, add them from the textboxs above.
Name
Value
isolation.tools.copy.disable
FALSE
isolation.tools.paste.disable
FALSE
isolation.tools.setGUIOptions.enable
TRUE
Click " OK ".
Power on the VM
Then use Copy/Paste directly on Windows/Linux/any other platform.
MailServer - Test SMTP
Your best, easiest and most globally available tool: telnet or Windows CMD
At command prompt, type: telnet mail.mailserver.com 25
Type EHLO , and then press ENTER.
Type AUTH LOGIN. The server responds with an encrypted prompt for your user name.
Enter your user name encrypted in base 64. You can use one of several tools that are available to encode your user name.
The server responds with an encrypted base 64 prompt for your password. Enter your password encrypted in base 64.
Type MAIL FROM:, and then press ENTER. If the sender is not permitted to send mail, the SMTP server returns an error.
Type RCPT TO:,and then press ENTER.If the recipient is not a valid recipient or the server does not accept mail for this domain, the SMTP server returns an error.
Type DATA.
If desired, type message text, press ENTER, type a period (.), and then press ENTER again.
If mail is working properly, you should see a response similar to the following indicating that mail is queued for delivery:
250 2.6.0 MAILID-SOMETHINGHERE@mail.somedomain.com.
ImageMagick - Install on Redhat 9 from Source
Installing ImageMagick 7 from Source Code
To install ImageMagick from source, you need a proper development environment with a compiler and related development tools. If you don’t have the required packages on your system, install development tools as shown:
sudo yum groupinstall 'Development Tools'
sudo yum -y install bzip2-devel freetype-devel libjpeg-devel libpng-devel libtiff-devel giflib-devel zlib-devel ghostscript-devel djvulibre-devel libwmf-devel jasper-devel libtool-ltdl-devel libX11-devel libXext-devel libXt-devel lcms-devel libxml2-devel librsvg2-devel OpenEXR-devel php-devel
Now, download the latest version of the ImageMagick source code using the following wget command and extract it.
sudo wget https://www.imagemagick.org/download/ImageMagick.tar.gz
sudo tar xvzf ImageMagick.tar.gz
Configure and compile the ImageMagick source code. Depending on your server hardware specs, this may take some time to finish.
sudo cd ImageMagick*
sudo ./configure
sudo make
sudo make install
Verify that the ImageMagick compile and install were successful.
sudo magick -version
Version: ImageMagick 7.0.8-28 Q16 x86_64 2019-02-19 https://imagemagick.org Copyright: © 1999-2019 ImageMagick Studio LLC License: https://imagemagick.org/script/license.php Features: Cipher DPC HDRI OpenMP Delegates (built-in): bzlib djvu fontconfig freetype jng jpeg lzma openexr pangoca
IPCamera - Different Configs
CAMERA LIST
MODEL
CONNECTION
ASH43-W
rtsp://admin:########@192.168.50.101:554/cam/realmonitor?channel=1&subtype=0
DAHAUA
HTTP:85
IP5M-T1179EW-AI-V3
HTTP:80
HPE - ProLiant DL380p Gen8 GPU Install
Supported GPUs for the HP ProLiant DL380p Gen8 are limited by the server's specific PCIe risers, 225W power constraints, and passive cooling requirements. Official and community-tested options include the NVIDIA GRID K1, K2 , Tesla P100 , Quadro K6000 , or consumer cards like the NVIDIA Tesla M4/M60
Because the DL380 G8 requires specific hardware components for proper installation, you will need to pay attention to the following details:
Hardware & Riser Kits: You will need the HP Double Wide Riser Cage Kit ( 662885-B21 ) and the Secondary GPU Riser ( 728543-B21 ) to accommodate double-wide or full-height GPUs.
Power Cables: Standard server power cables will not fit most NVIDIA GPUs. You will need a custom 10-pin to 8-pin GPU power cable to draw power from the motherboard.
Power Supply: Operating dual GPUs requires dual 1200W power supply units (PSUs) and two physical processors installed
BIOS Configuration: For advanced GPUs (like the Tesla P100), you must enter the BIOS, press Ctrl + A at the main screen to reveal the "Service Options," and enable PCI Express 64-bit BAR Support .
iLO & POST Issues: Many modern GPUs (like RTX series) can trigger POST code 5808, halting the boot process. Ensure your server has the latest BIOS update and iLO firmware to minimize compatibility issues.
Card Compatibility: The server officially supports specific enterprise cards like the NVIDIA Quadro K4000/K5000/P2000 and Grid K1/K2. Consumer cards (like the GTX 1050, GTX 1650, or RTX series) often require BIOS modifications, external power adapters, and custom chassis modification